Before installing the device, verify that your door controller and power supply align with the following technical parameters:

Based on technical documentation from dormakaba , the setup involves several critical steps:

Use a soft, damp cloth. Avoid aggressive cleaning agents that could damage the optical lens

: Use the provided self-adhesive mounting template to drill holes and secure the base plate. For swing door applications, the sensor should be mounted roughly 20–30 cm above the door edge near the hinges. prosecure opti combi manual english

The sensor is generally rated for temperatures between -15∘Cnegative 15 raised to the composed with power C +50∘Cpositive 50 raised to the composed with power C

I can provide the exact parameter values to optimize your sensor setup. Share public link

Every time you adjust the mechanical angle of the safety curtain, you must perform an environment teach-in: Before installing the device, verify that your door

The is a high-performance, dual-technology sensor engineered specifically for automatic sliding doors. By combining a microwave radar motion detector for door activation with an active infrared (AIR) safety curtain for threshold protection, it provides full compliance with European safety standards like EN 16005 and DIN 18650.

The safety curtain must drop precisely in front of the sliding door path without clipping the moving door panel itself, which would cause an endless loop of ghost openings. 5. Programming and Parameter Configuration

Refer to the ProSecure Opti Combi manual English (page 5-15) for detailed installation instructions. Here are the general steps: The sensor is generally rated for temperatures between

Safety is paramount when installing any automatic door system. The following points are critical:

If two sensors are close together, change frequencies to avoid interference. 🔍 Troubleshooting Potential Cause Door stays open Object in safety zone Clear the threshold of mats or signs. Door opens/closes randomly Vibration or rain Lower Radar sensitivity or change tilt angle. LED flashing Red Internal error Cycle power (OFF/ON) or check wiring. No detection No power / Incorrect wiring Check 12-24V input at the terminal block. ⚠️ Safety Precautions Always perform a "walk test" after installation.

Remove the main plastic cover of the sensor to expose the internal interface:

To reset the sensor, press and hold the main programming button for more than 5 seconds until the LED flashes rapidly, then release. 6. Troubleshooting Common Issues

Adjustable detection area and sensitivity.